OWL 500

Single-channel DC Current Data Logger

The OWL 500 data logger is a rugged and versatile data logger that records the popular 4-20mA process signal with ease and convenience. This logger is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters. All DC current process signals can be converted into custom engineering units using the simple equation editor of ACR's TrendReader software.

Our OWL Series consists of configurable, single-channel data loggers with flashing visual alarms, optical data transfer, and an industry-leading 10-year battery life.

Key Features

  • One channel with options to record temperature, electric current, voltage, or process current
  • 32KB memory for almost 33,000 readings
  • Configurable alarm thresholds and modes with super-bright red blinking annunciator  
  • Conformal coating protects electronics from harsh environments
  • Industry-leading 10-year battery life
  • 3-year warranty

Specifications

Size 60 x 48 x 19 mm (2.4 x 1.9 x 0.7 in)
Weight 54 g / 1.9 oz (All models except OWL 100-Poly)
80 g / 2.8 oz (OWL 100-Poly water-resistant model)
Case Material Noryl® plastic (All models except OWL 100-Poly)
Polyurethane (OWL 100-Poly water-resistant model)
Operating Limits -40 to 70°C (-40 to 158°F) and 0 to 95% RH (non-condensing) except OWL 100-Poly
Clock Accuracy +/- 2 seconds per day
Battery 3.6 volt Lithium
Memory Size 32 KB (32,767 readings)
Sampling Method Continuous (First-in, First-out)*, Stop When Full (Fill-then-stop)
*Not available for sample rates faster than 8 seconds
Sampling Rate User selectable rates from 5 per second to once every 12 hours
Resolution 8-bit (1 part in 256)
Communication Optical data transfer; data can be transmitted through glass or transparent medium up to 25 mm (1in)
Alarm Type Flashes red LED once every 8 seconds
PC Requirements Windows PC with a least 256MB RAM, 250MB of hard drive space and one free serial or USB port
Software Requirements TrendReader® (compatible with Windows 7, Windows 8 & Windows 10t)
Memory Size 32 KB
Input Range 0 to 24 mA DC
Accuracy +/- 1% of full scale
Input Impedance 100 ohms

 

 

SHOP AVAILABLE MODELS: 
Title:
Owl 500 - DC Current
SKU:
01-0254
Model: 
OWL-500

Single channel, 8 bit, 32 KB data logger (One 0-24 mA channel).

$360.00 USD