SmartReader Plus 5
3-channel temperature data logger
The SmartReader Plus 5 data logger is ideal for those applications that require monitoring extremely high temperatures or monitoring temperature over a wide range. The logger has one internal channel for measuring ambient temperature and two external channels for use with ACR thermocouple wire or any J, K, S, T or E type thermocouple wire.
Specifications
| Accuracy | +/- 0.5% of range + resolution |
|---|---|
| Thermocouple Specs | Range and Resolution: J type: -50 to 600ºC (-55 to 1100ºF); 0.30ºC (0.55ºF) K type: -100 to 1150ºC (-145 to 2100ºF); 0.50ºC (0.90ºF) S type: 0 to 1450ºC (32 to 2642ºF ); 1.0ºC (1.8ºF) T type: -200 to 400ºC (-325 to 750ºF); 0.40ºC (0.75ºF) E type: -50 to 680ºC (-58 to 1250ºF); 0.24ºC (0.44ºF) |
| Accessories | ACR Thermocouple Wire or any J, K, S, T and E type thermocouples |
Ordering Information
| Model | Memory | Catalog # |
|---|---|---|
| SRP-005 | 32KB | 01-0012 |
| SRP-005-128K | 128 KB | 01-0121 |