SmartReader Plus 7

8-channel process signal data logger

The SmartReader Plus 7 is a versatile data logger for easy recording of common process signal variables. With seven input channels, the logger is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters.

Specifications

Input Ranges - Standard Model 0 to 2.5 volts DC (1 channel)
0 to 5.0 volts DC (2 channels)
0 to 10.0 volts DC (1 channel)
0 to 200 millivolts DC (1 channel)
0 to 25 milliamps DC (2 channels)
Input Ranges - Other Models 0 to 2.5 volts DC (all external channels)
0 to 5 volts DC (all external channels)
0 to 10 volts DC (all external channels)
0 to 25mA DC (all external channels)
Accuracy +/- 0.5% of full scale
Overload Protection Voltage channels: +/- 40 volts (reverse-polarity protected)
Current channels: +/- 70 mA (reverse-polarity protected)
Input Impedance > 1 M ohm (200 mV channels)
> 1 M ohm (0 to 2.5 V channels)
> 1 M ohm (0 to 5.0 V channels)
> 1 M ohm (0 to 10.0 V channels)
20 ohm (0 to 25 mA channels)
Transducer Restrictions It is recommended to use a single power supply or loop isolators to avoid ground loops

Ordering Information

Model Memory Catalog #
SRP-007 32 KB 01-0014
SRP-007-128k 128 KB 01-0123
SRP-007-1.5M 1.5 MB 01-0152
SRP-007-0-2.5V 32 KB 01-0018
SRP-007-0-2.5V-128K 128 KB 01-0127
SRP-007-0-5V 32 KB 01-0107
SRP-007-0-5V -128K 128 KB 01-0124
SRP-007-0-5V-1.5M 1.5 MB 01-0154
SRP-007-0-10V 32 KB 01-0020
SRP-007-0-10V-128K 128 KB 01-0125
SRP-007-0-10V-1.5M 1.5 MB 01-0155
SRP-007-25mA 32 KB 01-0017
SRP-007-25mA-128K 128 KB 01-0126
SRP-007-25mA-1.5M 1.5 MB 01-0156