SmartReader Plus 7
8-channel process signal data logger
The SmartReader Plus 7 is a versatile data logger for easy recording of common process signal variables. With seven input channels, the logger is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters.
Specifications
| Input Ranges - Standard Model | 0 to 2.5 volts DC (1 channel) 0 to 5.0 volts DC (2 channels) 0 to 10.0 volts DC (1 channel) 0 to 200 millivolts DC (1 channel) 0 to 25 milliamps DC (2 channels) |
|---|---|
| Input Ranges - Other Models | 0 to 2.5 volts DC (all external channels) 0 to 5 volts DC (all external channels) 0 to 10 volts DC (all external channels) 0 to 25mA DC (all external channels) |
| Accuracy | +/- 0.5% of full scale |
| Overload Protection | Voltage channels: +/- 40 volts (reverse-polarity protected) Current channels: +/- 70 mA (reverse-polarity protected) |
| Input Impedance | > 1 M ohm (200 mV channels) > 1 M ohm (0 to 2.5 V channels) > 1 M ohm (0 to 5.0 V channels) > 1 M ohm (0 to 10.0 V channels) 20 ohm (0 to 25 mA channels) |
| Transducer Restrictions | It is recommended to use a single power supply or loop isolators to avoid ground loops |
Ordering Information
| Model | Memory | Catalog # |
|---|---|---|
| SRP-007 | 32 KB | 01-0014 |
| SRP-007-128k | 128 KB | 01-0123 |
| SRP-007-1.5M | 1.5 MB | 01-0152 |
| SRP-007-0-2.5V | 32 KB | 01-0018 |
| SRP-007-0-2.5V-128K | 128 KB | 01-0127 |
| SRP-007-0-5V | 32 KB | 01-0107 |
| SRP-007-0-5V -128K | 128 KB | 01-0124 |
| SRP-007-0-5V-1.5M | 1.5 MB | 01-0154 |
| SRP-007-0-10V | 32 KB | 01-0020 |
| SRP-007-0-10V-128K | 128 KB | 01-0125 |
| SRP-007-0-10V-1.5M | 1.5 MB | 01-0155 |
| SRP-007-25mA | 32 KB | 01-0017 |
| SRP-007-25mA-128K | 128 KB | 01-0126 |
| SRP-007-25mA-1.5M | 1.5 MB | 01-0156 |
More information
Related Articles
-
Using a Compound Line to Apply Average Value Calculations
-
How to troubleshoot incorrect readings for SmartReader and SmartReader Plus data loggers
-
Networking SmartReader Plus Data Loggers on Short Cable Run
-
Networking SmartReader Plus Data Loggers on Long Cable Run
-
Networking SmartReader Plus Data Loggers Remotely on Short Cable Run
-
Networking SmartReader Plus Data Loggers Remotely on Long Cable Run
-
Requirement for Proper Connection of Data Loggers to Modems and Ethernet Devices
Related Downloads
-
SmartReader Plus 7 Driver Patch for TrendReader 2 (v2.30 and v2.31)
Related FAQ
-
Frequently Asked Questions
-
Frequently Asked Questions for SmartReader 7 and SmartReader Plus 7