SmartReader Plus 7
8-channel process signal data logger
The SmartReader Plus 7 is a versatile data logger used for recording common process signal variables. With seven analog input channels and one temperature reference channel, the logger is ideal for monitoring where power is not available or a continuous record is needed. This 8-Channel Data Acquisition device is ideal for attaching to existing systems or new deployment. Application areas include HVAC Systems, Industrial Controls, Water and Wastewater. Critical parameters are measured at a preset time interval and the readings are stored giving a time and date stamp of when an event occured.
Ordering Information
| Model | Memory | Catalog # | Order |
|---|---|---|---|
| SRP-007-32K | 32 KB | 01-0014 | Buy Now |
| SRP-007-128K | 128 KB | 01-0123 | Buy Now |
| SRP-007-1.5M | 1.5 MB | 01-0152 | Buy Now |
| SRP-007-0-2.5V-32K | 32 KB | 01-0018 | Buy Now |
| SRP-007-0-2.5V-128K | 128 KB | 01-0127 | Buy Now |
| SRP-007-0-5V-32K | 32 KB | 01-0107 | Buy Now |
| SRP-007-0-5V -128K | 128 KB | 01-0124 | Buy Now |
| SRP-007-0-5V-1.5M | 1.5 MB | 01-0154 | Buy Now |
| SRP-007-0-10V-32K | 32 KB | 01-0020 | Buy Now |
| SRP-007-0-10V-128K | 128 KB | 01-0125 | Buy Now |
| SRP-007-0-10V-1.5M | 1.5 MB | 01-0155 | Buy Now |
| SRP-007-25mA | 32 KB | 01-0017 | Buy Now |
| SRP-007-25mA-128K | 128 KB | 01-0126 | Buy Now |
| SRP-007-25mA-1.5M | 1.5 MB | 01-0156 | Buy Now |
Specifications
| Input Ranges - Standard Model | 0 to 2.5 volts DC (1 channel) 0 to 5.0 volts DC (2 channels) 0 to 10.0 volts DC (1 channel) 0 to 200 millivolts DC (1 channel) 0 to 25 milliamps DC (2 channels) |
|---|---|
| Input Ranges - Other Models | 0 to 2.5 volts DC (all external channels) 0 to 5 volts DC (all external channels) 0 to 10 volts DC (all external channels) 0 to 25mA DC (all external channels) |
| Accuracy | +/- 0.5% of full scale |
| Overload Protection | Voltage channels: +/- 40 volts (reverse-polarity protected) Current channels: +/- 70 mA (reverse-polarity protected) |
| Input Impedance | > 1 M ohm (200 mV channels) > 1 M ohm (0 to 2.5 V channels) > 1 M ohm (0 to 5.0 V channels) > 1 M ohm (0 to 10.0 V channels) 20 ohm (0 to 25 mA channels) |
| Transducer Restrictions | It is recommended to use a single power supply or loop isolators to avoid ground loops |
![]()
More information
Related Articles
-
Using a Compound Line to Apply Average Value Calculations
-
How to troubleshoot incorrect readings for SmartReader and SmartReader Plus data loggers
-
Networking SmartReader Plus Data Loggers on Short Cable Run
-
Networking SmartReader Plus Data Loggers on Long Cable Run
-
Networking SmartReader Plus Data Loggers Remotely on Short Cable Run
-
Networking SmartReader Plus Data Loggers Remotely on Long Cable Run
-
Requirement for Proper Connection of Data Loggers to Modems and Ethernet Devices
Related FAQ
-
Frequently Asked Questions
-
Frequently Asked Questions for SmartReader 7 and SmartReader Plus 7