SmartReader Plus 9
2-channel pulse data logger
The SmartReader Plus 9 is a versatile data logger designed for easy counting and recording of switch contact closures and voltage pulses. It has two pulse/contact channels. Note for "switch status" logging - see SmartReader Plus 8
| Range | 4095 pulses/sample period |
|---|---|
| Accuracy | +/- 1 pulse/sample period |
| Input Voltage | Low = 0 to 0.5 volts DC High = 4.5 to 24 volts DC |
| Input Impedance | > 1.0 M ohm for Vin < 5V > 4.0 K ohm for Vin > 5V |
| Min. Pulse Width | 50% Duty Cycle: Slow input: 2 milliseconds Fast input: 10 microseconds |
| Maximum Frequency | 100 KHz |
| Switch Inputs | Input Type: Uncommitted “dry” contacts (relay or switch) Excitation: 5 microamps contact current 3.6 volts open circuit Contacts: Sealed gold-plated recommended |
Ordering Information
| Model | Memory | Catalog # |
|---|---|---|
| SRP-009 | 32 KB | 01-0016 |
| SRP-009-128K | 128 KB | 01-0130 |
More information
Related Articles
-
Using a Compound Line to Apply Average Value Calculations
-
Networking SmartReader Plus Data Loggers on Short Cable Run
-
Networking SmartReader Plus Data Loggers on Long Cable Run
-
Networking SmartReader Plus Data Loggers Remotely on Short Cable Run
-
Networking SmartReader Plus Data Loggers Remotely on Long Cable Run
-
Requirement for Proper Connection of Data Loggers to Modems and Ethernet Devices
Related FAQ
-
Frequently Asked Questions
-
Frequently Asked Questions for SmartReader 9 and SmartReader Plus 9